Coils are used as components of circuits, and to provide the magnetic field of motors, transformers, and generators, and in the manufacture of loudspeakers and microphones. In electrical engineering, coil winding is the manufacture of electromagnetic coils. JSTOR ( July 2016) ( Learn how and when to remove this template message).Unsourced material may be challenged and removed.įind sources: "Coil winding technology" – news Please help improve this article by adding citations to reliable sources. This is a big advantage of DPATT-3Bi that it can be used for Transformer Testing.This article needs additional citations for verification. On Pressing F2 button of the keypad of DPATT-3Bi instrument, the parameters of Short Circuit Test are displayed on the LCD as shown below.

Suppose the Full Load Current, 10.49A is obtained at 463.1V therefore the Impedance Voltage is 463.1V. % Impedance = (Impedance Voltage / Rated Voltage) * 100 Step 3 – Calculations: Now calculate Impedance Voltage (the voltage at which full load current is achieved) and then calculate % Impedance as per the following formula. Step 2 – Short Circuiting: Now short circuit LT side and apply the required voltage at HT side of electrical current transformer until the full load current is achieved. The value of Full Load Current for Transformers of different ratings is given below for reference. The values can be taken from name plate of the electrical current transformer rating:įull Load Current Formula = KVA Rating x 1000 / √3 x HV Line Voltage = 200 x1000 / √3 x 11000 Step 1 – Find Full Load Current: Calculate Full Load Current from parameters available in Transformer’s name plate as described below. Steps for conducting Short Circuit Test in Electrical Current Transformer You can see that LV side is short circuited and the voltage is applied at HV side. The following picture shows the arrangement for conducting Short Circuit Test using DPATT-3Bi. Therefore the watt meter measures only full load copper losses. Since the core losses are very small and can be neglected because applied voltage is very small as compared to the nominal voltage. After that full load current is applied on the primary side of the transformer. In this procedure the secondary winding (usually Low Voltage Side) of the transformer is short circuited. The short circuit test useful for measuring the winding losses of a current transformer and is conducted on the high voltage HV side of the transformer. Short Circuit or Full Load Test of Electrical Transformer This test is also known as no load test, iron loss test or core loss test. Now we shall learn more details about both the transformer loss measuring or testing procedures. On the other hand to measure the iron losses open circuit test is conducted.